| Subject: | Re: Dometic Thermistor Function? |
| From: | Michael Diehr |
| Date: | Mon, 14 Jul 2008 11:30:03 -0700 |
Perhaps I used the wrong term? I'm talking about the electrical gizmo, about the size of a 4 quarters stacked together, that the yellow wire connects to (the yellow wire powers the rear fan on/off). It's mounted on my dometic to the top set of fins on the back of the unit. It's a bit loose, and I'm wondering if it's important that it have a thermal contact with the fin, or if it just measures ambient air temp? On Jul 14, 2008, at 8:49 AM, Roger Sisler wrote: > That probe needs to be tight against the rear of the aluminum > evaporator. > Metal to metal contact. There is a channel along the entire length > of the > evaporator's rear that the probe sticks into. A plastic cord about > 1/8 inch > in diameter and 4 inches long presses in on top of it to keep it in > place. > That white cord should still be around. It is probably still in the > groove > and the probe just slipped out. > > It measures the temp of the aluminum plate.