| Subject: | Re: Dometic won't light troubleshooting |
| From: | azsun99 |
| Date: | Sat, 19 Jul 2008 12:45:13 -0700 |
A suggestion on the home-made manometer, is to mark the U on one side in half-inch increments, but number each as a whole inch. And I put green food coloring in the water to make it easier to see. And easier to stain everything when it sometimes blows out the other end when the gas is turned on :(. Worked for me. Jerry ----- Original Message ----- From: "Karl Mullendore" <groups@WESTYVENTURES.COM> To: <vanagon@GERRY.VANAGON.COM> Sent: Friday, July 18, 2008 11:09 PM Subject: Re: Dometic won't light troubleshooting > On Thu, 17 Jul 2008 09:33:46 -0700, Michael Diehr <md03@XOCHI.COM> wrote: > > >Update -- > > > >A homemmade manometer revealed that my (5 year old) Marshall 290 > >regulator was only putting out 7 inches of pressure. I stretched the > >spring and screwed the adjuster in full stop, which only took it about > >9.5 inches. So probably my regulator is failing. > > When you use your 'homemade' manometer, do you measure the differential > between the two water levels or only the rise in one side? Many people > measure only one side; the correct measurement is the total difference is > water level from one side of the U-tube to the other. > > > -- > No virus found in this incoming message. > Checked by AVG. > Version: 7.5.526 / Virus Database: 270.5.2/1562 - Release Date: 7/19/08 2:01 PM > >
Have something to add on this topic today? Revive this thread in the forum »