Skip to main content
Gerry | Vanagon
Checking account...
← vanagon.com home · Continue the discussion in the forum
Subject:Re: Bypassing low preasure switch
From:Jeff
Date:Sun, 10 Aug 2008 18:15:18 -0700

Chris,

No need to bypass the switch.  Just add the Freon and the additional
pressure will cause the switch to engage (if it works).  That's the normal
procedure.

Cheers,

Jeff

-----Original Message-----
From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf Of
Chris Snyder
Sent: Sunday, August 10, 2008 5:56 PM
To: vanagon@GERRY.VANAGON.COM
Subject: Bypassing low preasure switch

From what list members have told me, I need to bypass the A/C low pressure
switch to get the compressor to run so I can recharge the system.

What or how do I bypass this switch?

Thanks in advance

Chris S.   </HTML>