| Subject: | Re: Hydraulic valve adjustment question |
| From: | Scott Daniel - Turbovans |
| Date: | Wed, 13 Aug 2008 17:39:34 -0700 |
here's what's normal..........it's very clear when the rocker has contacted a lifter that is properly pumped up. On those you go the 1.5 turns past there. if it's squishy, like you say, which is a good way to describe it ........ what I do is go just a bit past contact and tighten down the rocker screw. Then later after it's run a while, I check them again. if any are stil squishy............I try to not go too far past initial contact. maybe a half turn. Seems a bit hard to tell when initial contact happens. Eventually they get quiet. ----- Original Message ----- From: "Jim Felder" <jim.felder@GMAIL.COM> To: <vanagon@GERRY.VANAGON.COM> Sent: Wednesday, August 13, 2008 3:23 PM Subject: Re: Hydraulic valve adjustment question > And what if a lifter is not firm? What's the procedure for a squishy > one, which was fine a few nights ago before it lay sideways in the > engine for a few days? > > Thanks, > > Jim > > On Wed, Aug 13, 2008 at 5:08 PM, miguel pacheco <mundopacheco@gmail.com> > wrote: >> Yup, just like the Idiot Manual taught me long ago! >> >> Gracias, >> Miguel >>