| Subject: | Re: Where does this relay go? |
| From: | Jim Felder |
| Date: | Fri, 20 Feb 2009 19:25:05 -0600 |
Alan and David, Either way I'm covered... I've got two more clusters. This sounds a little outside my soldering skills, david! Thanks, Jim On Fri, Feb 20, 2009 at 7:06 PM, David Beierl <dbeierl@attglobal.net> wrote: > At 06:28 PM 2/20/2009, Jim Felder wrote: >> >> It's the Level Control relay and I'm hoping it's what's causing my >> temp gauge to go nuts on really cold mornings. > > Jim, if it still "goes nuts" with the controller out, then it's an internal > gauge problem. It's fixable if you're up to some reasonably delicate > soldering. You have to drill out the face rivets, desolder the fine leads > to the heater coil, desolder and remove the circuit board from the mounting > posts, then replace the large capacitor, preferably with a tantalum, > observing polarity. Then put it all back. > > > -- > David Beierl - Providence RI USA -- http://pws.prserv.net/synergy/Vanagon/ > '84 Westy "Dutiful Passage," '85 GL "Poor Relation" >