| Subject: | Re: Surepower 1315 test report |
| From: | Jeffrey Vickers |
| Date: | Mon, 11 May 2009 14:48:34 -0700 |
The issue for me isn't the PD charger, its the solar panels. I don't want to charge the start battery with the solar panels so I need a way to shut down the connection to the start battery via the 1315. Since the ground won't do it, I'll have to add a switch to the hot lead connecting the 1315 to the start battery. Jeff On May 11, 2009, at 1:39 PM, Automatic digest processor wrote: > Date: Sun, 10 May 2009 17:19:37 -0700 > From: Keith Ovregaard <kovregaard@GMAIL.COM> > Subject: Re: Surepower 1315 test report > > Thanks for the helpful info, Dennis. The Progressive Dynamics PD9130 > looks like a good way to go, but that purchase will have to wait. In > the meantime, I will make sure that the battery being charged is > disconnected. > > PS: Oops, I meant to write Schumacher, not Shcumaker
Have something to add on this topic today? Revive this thread in the forum »