| Subject: | Re: Propex and getting gas tight fittings |
| From: | Frank Condelli |
| Date: | Tue, 9 Jun 2009 06:09:07 EDT |
In a message dated 07/06/2009 7:01:37 A.M. Eastern Daylight Time,
LISTSERV@GERRY.VANAGON.COM writes:
Absolutely correct ! HOWEVER, the connection he's trying to make
is NOT behind the fridge but to one of the supply lines to the fridge or
stove under the sink. Very easy to access and if the compression fittings
are installed correctly on perfectly round tubes they work correctly.
Otherwise everyone who does these installs needs a flaring tool. Yes, the flare
connection is the better way BUT the compression fittings work. I have
done many of them with no leaking.
>>>>>Neither flare fittings nor compression fittings require tape. Only
threaded joint connections require tape or paste. I'm not sure where this
information comes from, but I believe it to be incorrect. If someone can show
me proof to the contrary, I will gladly eat crow on this one, but I'd like
to see gas connections be safe.<<<<<<
Cheers,
Frank Condelli
Almonte, Ontario, Canada
'87 Westy & Lionel Trains (_Collection for sale_
(http://frankcondelli.com/trainsal.htm) )
_Frank Condelli & Associates_ (http://frankcondelli.com/busindex.html) -
Vanagon/Vanagon Westfalia Service in the Ottawa Valley
_Vanagon Stainless Steel Exhaust Systems_
(http://frankcondelli.com/exhaust.htm)
_BusFusion_ (http://www.busfusion.com/) a VW Camper camping event,
Almonte, ON, June 11 ~ 14, 2009Have something to add on this topic today? Revive this thread in the forum »