| Subject: | Re: Gas Tank Blowing Fuel Out When Filled |
| From: | Max Wellhouse |
| Date: | Wed, 29 Jul 2009 17:21:55 -0500 |
I had this happen several years ago and long enough ago that I don't specifcally rememberr what I did to rmedy it, but the cause was the clogged vent pipe that runs right under the filler nozzle. I think I had sealed a connection with some siliicone and it swelled up blocking the airflow or something like that. MOTS: Don't silicone your fuel lines!! DM&FS At 04:38 PM 7/29/2009, Robert Stewart wrote: >I replaced the tank at the time of the installation of the kit. I have >a feeling they screwed something up. > >My mechanic upstate here is going to look at the tank either tonight >or later this week. > >I really think it has got to be something simple. It has a new tank >that is not even a year old, the new tank seal kit and all new fuel >lines. So to me it sounds like a improperly installed component or >possibly a bad hose to or from the expansion tanks. > >Thanks Ken. > >Robert >NY > >On Jul 29, 2009, at 9:44 AM, Ken Wilford wrote: > >>Robert, >> >>It sounds like either an improper install or a rust hole in the top >>of the gas tank. What I normally do is fill the tank and then feel >>on the top of the tank to find the leak. It is possible that they >>didn't tighten up something properly and it popped off during the >>fill up. Let me know if I can help you further. >> >>Ken Wilford >>John 3:16 >>www.vanagain.com >> >> >>Robert Stewart wrote: >>>So I had an one of my old mechanics in NYC install the Vanagain Gas >>>Tank Seal Kit. Either they did not do the job right or something else >>>is wrong. >>> >>>Every time I fill the tank and let the gas stations pump auto shut >>>off >>>when filled it blows of out of the bottom near the rail that mounts >>>the tank on the passenger side. I can see the fuel spill out and down >>>the rail onto the floor. It's not a huge amount but it is dangerous I >>>want to solve the problem. >>> >>>Could it be that they did not install one of the 3 rubber grommets >>>properly? >>> >>>Or Could it be something with the expansion tanks that link to the >>>gas >>>tank? >>> >>>Looking for suggestions... >>> >>>The strange thing about this issue was the first time I filled up >>>after it was just installed it did not blow out, but all fill ups >>>after did! >>> >>>Strange. >>> >>>Any help would be appreciated as always. >>> >>>Robert >>>Bloomingburg NY >>>88 Wolfsburg, Silver >>>239,700 miles - automatic >>>AIM: rmstewart@mac.com
Have something to add on this topic today? Revive this thread in the forum »