On 9/9/2009 10:45 PM David Beierl wrote:
> At 08:42 PM 9/9/2009, Rocket J Squirrel wrote:
>> I have a Ken Lewis O2 meter and during the initial open-loop
>> operation, it
>> read normally, in the middle of the scale, even when running poorly.
>
> Until the sensor heats up to ?600F? or so it won't output a signal, and
> the level you see on the bar graph represents the bias placed on the
> line by the ECU.
Oh. Well, /there's/ my problem!
--