| Subject: | Re: Suburban Type Furnace Install; |
| From: | Rocket J Squirrel |
| Date: | Thu, 29 Oct 2009 20:51:53 -0700 |
How long a run would that have to be to get a return on investment?
(Too sleepy to do the math)
--
Mike "Rocket J Squirrel" Elliott
84 Westfalia: Mellow Yellow ("The Electrical Banana")
74 Westrailia: (Ladybug Trailer company, San Juan Capistrano, Calif.)
Bend, OR
KG6RCR
On 10/29/2009 7:31 PM Karl Mullendore wrote:
>> Important to recognize is that furnace blowers draw current. This one, the
>> 16,000 btu Suburban NT-16SE, wants 2.8 amps when running. One hour of
>> operation is 2.8 amp-hours, size your aux battery accordingly.
>
> Also worth considering: the Atwood/Hydroflame furnaces are only 75%
> efficient when running perfectly - Propex heaters are 95%. Throwing away a
> gallon of propane for every three that results in heated air seems a bit
> wasteful, not to mention fouling the environment more. Might that make the
> efficient Propex a better deal in the long run?
>
> Karl
>Have something to add on this topic today? Revive this thread in the forum »