| Subject: | Re: 1982 Westy Alternator question |
| From: | David Beierl |
| Date: | Thu, 5 Nov 2009 18:12:29 -0500 |
Hi Steve, At 08:21 AM 11/5/2009, zzyzx wrote: >Is the voltage regulator internal on a stock 1982 air cooled vanagon >alternator? Yes. >Where does the blueish green wire run to out of the back of the alternator? The two 12-ga red wires run in parallel from the B+ alternator terminal to the 30 terminal on the starter, where they connect to a 1-ga wire to the battery. The blue wire goes from the D+ terminal to the alternator light circuit in the panel. This circuit is dual-purpose; as well as warning, it's also needed to start the alternator charging. Bentley 97.20, current tracks 28-32. Yours, David
Have something to add on this topic today? Revive this thread in the forum »