Good suggestion. Given that the coil to dist wire was compromised I'm willing to believe that the wires may be the culprit. What puzzles me though is why I can get it to start from cold with a little throttle. I then have to hold it at idle or it will die. That seems to me to be more fuel/air/throttle boy to me. Perhaps TPS? m On Fri, Dec 4, 2009 at 11:04 PM, A J <flavanagon@gmail.com> wrote: > This is something that has happened to me several times and although it > is simple and might be overlooked its worth a shot. Because the motor > was running while you powerwashed and ran afterward even if it was for a > hundred miles dont overlook the possibility of -- steam. The water will > vapor to steam INSIDE the dist cap and while running have no effect but > when you shutdown and let it cool it condenses and becomes water > droplets that simply short the cap and prevent the proper spark causing > it not to start. It may even start but not without effort and will run > poorly. > I would suggest a second look at the electricals and make quite sure > they are all dry. I normally leave the cap off after drying for several > hours to be sure that the cap and dist are dry. The same holds true of > the wires and their connections in the cap aand coil. > Just my two cents worth > -- mordo 1990 Carat