| Subject: | Re: heater fan whine |
| From: | Robert Keezer |
| Date: | Mon, 25 Jan 2010 20:32:10 -0800 |
C'mon guys, this is classic thread hijacking. The OP asked how to fix the whine in the motor, not load reduction. I want to know the answer also. � Robert 1982 Westfalia � --- On Mon, 1/25/10, David Beierl <dbeierl@ATTGLOBAL.NET> wrote: From: David Beierl <dbeierl@ATTGLOBAL.NET> Subject: Re: heater fan whine To: vanagon@GERRY.VANAGON.COM Date: Monday, January 25, 2010, 7:16 PM At 05:58 PM 1/25/2010, John Rodgers wrote: >This thread brings to mind having seen somewhere something about using a >relay(relays) to reduce the load on the front heater control switch. > >Anyone have a link showing this??? Use the high-speed position on the switch to drive the 86 terminal on a 20-amp relay; ground the 85 terminal.� Use the 87 terminal to drive the high-speed wire to the fan.� On a 2.1l feed the 30 terminal from the switch feed wire, but on a 1.9l run a separate fused circuit to feed the 30 terminal. The two lower-speed positions aren't overloaded so they don't need any help. Yours, D
Have something to add on this topic today? Revive this thread in the forum »