| Subject: | Re: Starter Help! |
| From: | Mark A Kippert |
| Date: | Sun, 14 Feb 2010 09:19:50 -0500 |
I recently found that my starter had failed because the short ground that runs from the starter body to the solenoid had disintegrated. It looked fine until I started brushing it clean to inspect it, then it fell apart. I bought the van non-running so I don't know if there were any symptoms leading up to it's failure. Mark K 1986 GL/2WD/4SPD "Old Gold" 1990 Carat/2WD/Auto "Carol" On Feb 13, 2010, at 3:35 PM, Kevin Plichta wrote: > My 91 starter not turning. I here the fuel pump come on, there is 12v at the main starter lead and less than 4 at the solenoid when turning the key. When I disconnect the solenoid lead and turn the key there 12v. So under a load is when I think is the problem but what ?? I had the starter tested at a shop and worked. Some history, this past fall the short braided cable between the starter and solenoid was replaced at a shop. > Thanks again for your wisdom!! > Kevin Plichta > > _________________________________________________________________ > Your E-mail and More On-the-Go. Get Windows Live Hotmail Free. > http://clk.atdmt.com/GBL/go/201469229/direct/01/
Have something to add on this topic today? Revive this thread in the forum »