| Subject: | Re: Voltage surges |
| From: | David Beierl |
| Date: | Fri, 21 May 2010 19:01:54 -0400 |
At 06:33 PM 5/21/2010, Mike \"Rocket J Squirrel\" wrote: >Mister Oscilloscope shows that the voltage surge is about 300mv in >amplitude, occurs every 1.04 seconds, and is about 100ms in >duration. None of these features change with additional circuit >loading (e.g., turning on the headlights), nor with engine rpm. > >This doesn't sound to me like a voltage regulator problem. Nope, me either. Gotta be a load, and I think you've nailed it below. Though I'm curious that it's an increase and not a decrease. >I wonder if I've got an active load of some sort pulling on the >electrical generation system, such as my DC > DC battery charger >which can haul up to 15A out of the system for charging the deep >cycle house battery. Lots of modern battery chargers will pulse-charge at more-or-less full output once the battery leaves the deep-drained condition. d