| Subject: | Re: deep cleaning westy water tank |
| From: | Alistair Bell |
| Date: | Tue, 3 Aug 2010 17:24:18 -0700 |
I used the hardware store muriatic acid (hate the old names :)), which is about 37% HCl, or about a 11.1 Molar solution. Just incase folks were wondering :) On a more serious note, I should have mentioned eye protection etc, and, DO NOT add water to acid, but add the acid to the water. Just remember the phrase "never give acid a drink" cheers alistair On 3-Aug-10, at 4:48 PM, Larry Alofs wrote: For those who do not have access to a lab stockroom, we might mention that HCl is also available at hardware stores, etc, as muriatic acid. Do not use full strength. I would dilute with water about 3:1. Wear eye protection and if it gets on your skin, wash it off promptly. Better living thru chemistry. Larry A. On Mon, Aug 2, 2010 at 9:12 PM, Alistair Bell <albell@shaw.ca> wrote: > Another scintillating post :) > > I cleaned out the water tank with a solution of HCl, before and after > pics here: > > http://shufti.wordpress.com/2010/08/02/westy-water-tank-cleaning/ > > > alistair >
Have something to add on this topic today? Revive this thread in the forum »