| Subject: | Re: Hot A/C Wire |
| From: | David Beierl |
| Date: | Mon, 23 Aug 2010 17:14:56 -0400 |
At 01:02 PM 8/23/2010, Raimund Feussner wrote: >But 60A is the official Ford-rating for 6sqmm wire. I take it they don't subscribe to DIN VDE 0298 part 4, as quoted on p. 792 of Bosch Automotive Handbook, 4th Edition? It gives max continuous of 54 A @30C/86F, 38.3 A @50C/122F for PVC-insulated wire with 70C/158F max working temp. Given engine-compartment temps, VW is violating those limits by fusing a 6 mm^2 wire at 50 amps. Yours, David