Subject:Re: Hot A/C Wire
From:David Beierl
Date:Mon, 23 Aug 2010 17:14:56 -0400

At 01:02 PM 8/23/2010, Raimund Feussner wrote:
>But 60A is the official Ford-rating for 6sqmm wire.

I take it they don't subscribe to DIN VDE 0298 part 4, as quoted on
p. 792 of Bosch Automotive Handbook, 4th Edition?  It gives max
continuous of 54 A @30C/86F, 38.3 A @50C/122F for PVC-insulated wire
with 70C/158F max working temp.

Given engine-compartment temps, VW is violating those limits by
fusing a 6 mm^2 wire at 50 amps.

Yours,
David