| Subject: | Re: Propex heater or regulator |
| From: | Karl Mullendore |
| Date: | Wed, 24 Nov 2010 18:13:58 -0500 |
I would caution messing about with regulator adjustment without having a water-column gauge handy. The fact that it had been working fine to this point means the regulator is probably adjusted correctly. Turning it out two turns would drop the pressure significantly, BTW. Re: the comment that a Suburban heater 'fits': I'd love to see photos! All of the current models are far too large to fit, and produce such a large amount of heat that they seem ill-suited for van application. Karl www.propexusa.com On Wed, 24 Nov 2010 14:30:31 -0800, Clint Carson <ccarson26@YAHOO.COM> wrote: >Danny, >Many regulators are somewhat adjustable. >And Many heaters including Propex >have a problem lighting >with European and otherwise tanks/regulators. >There will be a cap on top of the regulator. >(if you have the adjustable type) >remove that and underneath is a >hex socket. >Turn it ccw or out 1 to 2 turns. >This should keep you burning (man)