| Subject: | Re: Start Issue with Hard Start Relay |
| From: | Scott Daniel - Turbovans |
| Date: | Sun, 6 Mar 2011 19:16:44 -0800 |
Sounds high to me. 37 amps going through the ignition switch 'start' contacts ? just doesn't sound likely to me. there are two levels of current btw ..in the solenoid circuit.. one is the energize current., the other ...less I believe, is the 'hold' current. mark drillock could comment on that. ----- Original Message ----- From: "Larry Alofs" <lalofs@GMAIL.COM> To: <vanagon@GERRY.VANAGON.COM> Sent: Sunday, March 06, 2011 6:20 PM Subject: Re: Start Issue with Hard Start Relay A while back I connected a starter to a car battery so that I could measure the current in that solenoid circuit. It seems to me that it was around 37 amps. That is an awful lot thru a 1/4 inch push-on connector as well as the ignition switch. If the crimp of that connector to the wire is a little corroded, the resistance will produce a lot of heat. If anyone else has measured this current, I would welcome confirmation or refutation. Larry A. On Sun, Mar 6, 2011 at 6:19 PM, Michael Sullivan <sandwichhead@gmail.com> wrote: > Just getting ready to put in the Hard Start Relay and noticed this wire on > my new Bosch starter with some melted plastic. Just installed the new > battery and ign switch and wondering if I should go fwd with the install > or > switch out the starter first. Thanks to all. > Michael in San Antonio > 91GL Weekender AT 2.1L 'Gringo' >
Have something to add on this topic today? Revive this thread in the forum »