Subject:Re: Reed Switch/water level sensor
From:David Beierl
Date:Fri, 18 Mar 2011 16:27:29 -0400

At 04:03 PM 3/18/2011, Troy wrote:
>I will break out the solder gun and get busy! Wish me luck.

Erm...can be done, but you'll have a much easier time of it with a
fifteen or twenty watt iron.  Well - a somewhat easier time, I
guess.  Everything's out in the open there, plenty of room.  Just be
absolutely sure to leave slack in all the leads but most especially
the reed switch ones.  You'll have to resolder all the existing
ones.  Once that's done the wand will be able to flex a bit without
instant disaster.

d
ps - it goes without saying, but - electronic flux-cored 60/40 or
63/37 solder.  Don't even think of plumbing solder and flux.