| Subject: | Re: 1983 Westy Propane Tank Question |
| From: | Richard A Jones |
| Date: | Sun, 20 Mar 2011 09:00:55 -0600 |
> But if they don't open the bleed screw ALL THE WAY = > before they try to fill, it can pressure lock and then you have a harder ti= > me if the guy doesn't know how the pressure relief valve works. That's the key. For the auto-stop valve, it must be fully open. But the reason propane jockeys don't know to do that is the typical (99.9% of tanks) bleeder valve needs to be open just a crack to vent when they fill the tank. When they see propane from the bleeder, it is full. For the auto-stop to shut off the valve automatically, it must be fully open. So two reasons to replace the auto-stop with a regular fill valve and a regular bleeder valve: (1) the auto-stops are very old and may be failing, and (2) propane guys will know how to fill the tank without coaching. Richard