| Subject: | Re: Front Heater Core Shutoff |
| From: | Jake de Villiers |
| Date: | Tue, 28 Jun 2011 10:34:36 -0700 |
That's why I'm recommending a forged 1/2" ball valve - full diameter inside makes a big difference. And the 1/2" copper stubs are just about 5/8" on the outside to match your heater hose. Avasilable at Rona for about $11.00 my cost. On a side note, replacing the gate valves in your house with this type of valve will give about 40% more volume at the taps. Replacing the lines with 3/4" copper plus these valves will just about double it. ;) As an added bonus, there is no noise from these valves because there is no turbulence induced. On Fri, Jun 24, 2011 at 12:58 PM, Richard A Jones <Jones@colorado.edu>wrote: > A comment on the valves Terry Kay sells on his site++. They > are good, brass, Italian valves with fittings that go right > into the hose, making installation very easy. However, > the diameter of the hole in the ball of the valve is > smaller than the heater hose diameter by quite a bit. So > it reduces the flow. That affects the front heater in > very cold weather. > > ++ http://community-2.webtv.net/VanStuff/VanagonWestfalia > > Richard > -- Jake 1984 Vanagon GL 1.9 WBX - 'The Grey Van' 1986 Westy Weekender/2.5 SOHC Subie - 'Dixie' Crescent Beach, BC www.thebassspa.com www.crescentbeachguitar.com http://subyjake.googlepages.com/mydixiedarlin%27