| Subject: | Re: V-Belt tightness -- how to determine |
| From: | Karl Wolz |
| Date: | Wed, 24 Aug 2011 20:34:30 -0700 |
Note that I mentioned I didn't use nearly the force that would have been afforded by the crowbar; I only pulled on it with 20 - 30 lbs pressure. Nice to have one hand on the crowbar and the other still available to tighten the bolt. Karl Wolz |-----Original Message----- |From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] |On Behalf Of Mike Riley |Sent: Wednesday, August 24, 2011 7:36 PM |To: vanagon@GERRY.VANAGON.COM |Subject: V-Belt tightness -- how to determine | |a word of warning |most belts sold for replacement at a flaps are the wrong size |and sit too high in the groove. |they Do NOT grip at an acceptable amount of tension. you need |the proper metric width belt and put it on and tension until |it does not squeal. This occurs at a lower tension that the |fatter belt commonly sold. |I feel that reefing on the alternator with crowbars causes the |litany of broken alternator mounts and bad alternator and |water pump bearings. the point is to get it to work properly |and not damage anything not have it conform to some arbitrary |setting.BTW the bently assumes that the proper width belt is used. |mike |----- |No virus found in this message. |Checked by AVG - www.avg.com |Version: 10.0.1392 / Virus Database: 1520/3854 - Release Date: |08/24/11
Have something to add on this topic today? Revive this thread in the forum »