| Subject: | Re: Mullendore port help |
| From: | David Beierl |
| Date: | Tue, 4 Oct 2011 23:41:54 -0400 |
At 08:57 PM 10/4/2011, Edward Maglott wrote: >I found my once squealing heater was not working at all and it's fuse >was blown. It had a 25A fuse, which was supposed to be 30 according >to Bentley. I put in a 30A and it is back running but I wanted to do >the Mullendore port lubrication. On a 2.1l that ought to be a 20 amp fuse, pretty sure. On a 1.9l prolly a 16 amp? > I drilled the hole as specified and >got a light in there through the big air inlet opening but I do not >see the motor. It is supposed to be straight back? If I look >straight back I see a rectangular opening that looks like it might be >about 5" wide and 2" tall. Look to the left of that opening, and closer to you. Yours, David