| Subject: | Re: hydraulic lifter adjustment questions (sorry) |
| From: | Stuart MacMillan |
| Date: | Tue, 22 May 2012 19:35:56 -0700 |
Probably, but the valves will not close completely, giving you a very poorly running engine and low compression. If you go too far you could bend a valve. Stuart From: pickle vanagon [mailto:greenvanagon@gmail.com] Sent: Tuesday, May 22, 2012 1:21 PM To: Stuart MacMillan Cc: vanagon@gerry.vanagon.com Subject: Re: hydraulic lifter adjustment questions (sorry) Ok this makes sense. So, even if they're pumped up and not soft, when you back off the adjuster screws they should expand a bit more. I think now I remember this happening when I did it way back when. But what about the other question... can I be adjusted too far out without having lifter noise? I.e., should I just wait for noise before bothering to adjust the lifters, or are there negative consequences of too-far-out adjustment which don't carry lifter noise? On Tue, May 22, 2012 at 2:50 PM, Stuart MacMillan <stuartmacm@gmail.com> wrote: There is an internal spring. That's what you are compressing a bit when you do however many turns in you decide to do! Stuart Wes Wrote: Something I've remained confused about despite years of seeing threads on this adjustment issue is this: When you adjust the lifters to some number of turns in, how do you know the lifters were already pumped to their full length before you did the adjustment? Isn't the whole point of the lifters (assuming they work as they were intended) that they can pump up to a partial length? It almost seems to me that you would have to adjust them way out, run the engine to pump them up, and then adjust them in. Why isn't that necessary? Thanks for any insights!! Wes
Have something to add on this topic today? Revive this thread in the forum »