| Subject: | Re: Factory Hose Clamps |
| From: | JRodgers |
| Date: | Sat, 9 Jun 2012 10:38:08 -0500 |
Dennis, one thing we were taught in aviation mechanic school that I think might apply here is - if a specified torque value nor a standard torque value is not available, then finger-tight-plus-a quarter-turn was the principle applied. None of this "tighten 'til you can't turn it no 'mo " stuff. A variant of that might be to "snug it up - then a quarter turn" where screw clamps are concerned. I think that is safe enough. John On 6/9/2012 9:00 AM, Dennis Haynes wrote: > The pinch type hose clamps are also a compensating type clamp when pinched > with the proper tool. That pinch can flex. It is used for both speed of > installation and reliability. Unless you are using a torque wrench on a > screw clamp you have no idea if it is being properly installed. Luckily hose > connections tend to be reliable so we usually get away with anything. There > are times where screw clamps are the best choice but stainless alone does > not make them lifetime, especially with a stainless screw and nut. The > stainless hardware will not give a consistent clamp load to a given torque > when re-used. > > Dennis