| Subject: | Re: 87 vanagon quit while driving |
| From: | neil n |
| Date: | Wed, 26 Sep 2012 10:59:50 -0700 |
Hi Mark. I may be wrong, but when key turned to ign. on (15 power only)..... B+ --> Digifant relay --> FI's If meter probes on FI positive and frame, current measured may Digifant relay load (coil) and/or wire resistance. i.e. a small current may be normal. But maybe "cut the key on" means turning key to 50 (engaging starter)? This would mean that FI's pulse on/off. Though I don't think a failed or failing FI is the issue, (poss. engine flooding cued me to this) FWIW, resistance value for FI's on 2.1: each FI (unplugged) 15-20 Ohms. Via 12 & 14 of ECU connector (ONE FI plugged in at a time) same. Mark Drillock posted this neat bypass tool: http://www.thesamba.com/vw/forum/viewtopic.php?t=349429&highlight=bypass Owner/shop should read the post, but AFAIK, it takes battery + directly to certain components/points, thus bypassing common trouble spots; ign. switch, relays. IMO, tool likely only useful if owner can properly assemble it. Shop $ to make it likely better spent trouble shooting via Bentley methods. Neil. Neil. On Wed, Sep 26, 2012 at 9:49 AM, Mark Dearing <VWBrain@aol.com> wrote: > have a friend who is stranded in jersey, he found a shop to help, tech > says the injectors have a faint current when you cut the key on, engine seems > to be flooded. any ideas? thanks mark d -- Neil n 65 kb image Myford Ready For Assembly http://tinyurl.com/64sx4rp '88 Slate Blue Westy to be named. '81 VanaJetta 2.0 "Jaco" http://tubaneil.googlepages.com/ Vanagon VAG Gas I4/VR Swap Google Group: http://groups.google.com/group/vanagons-with-vw-inline-4-cylinder-gas-engines
Have something to add on this topic today? Revive this thread in the forum »