| Subject: | Re: Radiator fan on without key |
| From: | David Beierl |
| Date: | Mon, 1 Oct 2012 17:01:17 -0400 |
At 04:08 PM 10/1/2012, Jamie Auch wrote: >An interesting thing happen today. My wife was using the '89 Westy >and she called and said the fan was still running with the Westy >turned off. I did not think much of it until I got home and the fan >was running three hours later. I should say barely running because >the battery was almost dead. What would cause this? I can keep the >fan off by either unplugging the switch under the grille or pulling >#1 fuse correct? Can anyone tell me what might have happened? Unplug the switch at the radiator. If the fan stops, bad switch. If that's not it, normally either the fan relay on the fuse/relay panel or if you have A/C another control relay Yes, pulling S1 should stop the bleeding without diagnosing the issue. Since the fan motor is highly inductive, I'd expect a considerable arc when you unplug the fuse, so not recommended to do it a lot with the fan running. Yrs, d