| Subject: | Re: AC 134a refrigerant leak down |
| From: | Tom Hargrave |
| Date: | Tue, 7 May 2013 19:50:51 -0500 |
Was it holding R12 fine? It could be the seal in the front of the compressor - that seal depends on a oil film to not leak. I've seen a lot of R12 systems that barely leaked start leaking a lot when converted to R134 just because the molecule size is smaller & the gas passed through the compressor front seal easier. Thanks, Tom Hargrave www.stir-plate.com www.towercooler.com www.kegkits.com www.grow-sun.com -----Original Message----- From: Vanagon Mailing List [mailto:vanagon@GERRY.VANAGON.COM] On Behalf Of JRodgers Sent: Tuesday, May 07, 2013 3:50 PM To: vanagon@GERRY.VANAGON.COM Subject: AC 134a refrigerant leak down 18 months ago I had the AC system gone completely through - and converted to R134a. It got new seals and the whole nine yards. the system ran great through the hottest months but then began to show signs of 134a leakage by virtue of reduced cooling. That got progressively worse. Twice I added refrigerant, but the cooling has once again dropped off. Givben this - obviously I have a leak. I was wondering about the application of one of those sealers to the refrigerant? Do they really work?? I dropped a bundle to get this fixed, and would hate to have to do it again.!! Recommendations? Thanks, John Rodgers Birmingham, AL ----- No virus found in this message. Checked by AVG - www.avg.com Version: 2013.0.3272 / Virus Database: 3162/6305 - Release Date: 05/07/13
Have something to add on this topic today? Revive this thread in the forum »