| Subject: | Re: A/C tools question |
| From: | Eric Ley |
| Date: | Fri, 10 May 2013 12:11:50 -0400 |
In Quebec it is illegal to put Freon or top off a system that has not been leak tested and it might be for the rest of Canada as well. Eric Ley Garage Mechanic ELM 2001 Demers Franklin, Qc -------------------------------------------------- From: "Stephen Grisanti" <bike2vcu@YAHOO.COM> Sent: Friday, May 10, 2013 11:17 AM To: <vanagon@GERRY.VANAGON.COM> Subject: Re: A/C tools question > " But oddly enough it's not illegal to top off a known leaky system even > though you are indirectly doing the same thing!" > May not be illegal but it seems like "responsible" shops refuse to do it. > Even the guys who gave me the scary-high repair estimate would not top off > the original R12 and send me on my way with the bill for that fix. That > is what prompted me to try the cheapo R134a conversion in the first place. > Stephen > > --- On Thu, 5/9/13, Tom Hargrave <thargrav@HIWAAY.NET> wrote: > > From: Tom Hargrave <thargrav@HIWAAY.NET> > Subject: Re: A/C tools question > To: vanagon@GERRY.VANAGON.COM > Date: Thursday, May 9, 2013, 10:24 PM > > When R12 was more common I used to borrow a friend's setup & give him the > reclaimed R12 for the trouble. These days I would have a shop pull a > vacuum. > > Just remember a "empty" R12 system is still full of R12, it's just R12 at > atmospheric pressure of ~14.6 PSI. And it's just as illegal to > intentionally vent that gas into the atmosphere as it is to vent > pressurized gas into the atmosphere. But oddly enough it's not illegal to > top off a known leaky system even though you are indirectly doing the same > thing! > > Thanks, Tom Hargrave > www.stir-plate.com > www.towercooler.com > www.kegkits.com > www.grow-sun.com > > > > -----Original Message----- > From: Vanagon Mailing List [mailto:vanagon@GERRY.VANAGON.COM] On Behalf Of > Todd Last > Sent: Thursday, May 09, 2013 10:21 AM > To: vanagon@GERRY.VANAGON.COM > Subject: A/C tools question > > For those who work on their A/C, how do you recover the refrigerant and > evacuate the system so you can do repairs? > Does anyone own their own A/C recovery unit? Or do you take it to the > local A/C shop? > > What are the best strategies & what are the favorite tools? > For example, if you need to replace the compressor - what it the best DIY > strategy? > > BTW - if you want to buy R-12 you have to get EPA609 certification. > http://www.epatest.com/609/ > > > thanks, > Todd > '88 Westy > > > ----- > No virus found in this message. > Checked by AVG - www.avg.com > Version: 2013.0.3272 / Virus Database: 3162/6310 - Release Date: 05/09/13 >
Have something to add on this topic today? Revive this thread in the forum »