| Subject: | Re: Arduino and Vanagons |
| From: | David Beierl |
| Date: | Wed, 4 Dec 2013 14:46:44 -0500 |
At 11:33 PM 12/3/2013, James wrote: >Distributor rotates at half crankshaft speed.... idle is 850 rpm.... >half is 425 rpm... one Hall Effect signal >per crankshaft rotation ( or is that two per rotation...??).... nah, >I'd better try to calculate this tomorrow! One pulse per (piston @ TDC** on firing stroke) so two per crankshaft revolution. 850 rpm / 60 secs/minute = ~14 rev/second x 2 pulses/rev = ~28 pulses/second. ** Really at the fixed timing advance point which is a few degrees before TDC on the 2.1l. Yrs, d
Have something to add on this topic today? Revive this thread in the forum »