| Subject: | Re: Westy water tank level indicator problem |
| From: | David Beierl |
| Date: | Tue, 8 Jul 2014 12:27:22 -0400 |
At 10:00 AM 7/8/2014, Richard A Jones wrote: >Any ideas or experience or knowledge? David? ;-) > >Richard Quick answer, more later. 1) You can test the input with a potentiometer and voltmeter. Input lead is biased to B+ with one megohm, electrodes ground out successive resistors in a voltage divider inside the little black module by the tank. Result compared against similar network at the left-side LM324 chip. 2) The LM324 chips die a lot. 3) Some info and schematics here Gotta go, back later. d
Have something to add on this topic today? Revive this thread in the forum »