| Subject: | Re: NVC [Friday] Natural Gas regulator |
| From: | Rocket J Squirrel |
| Date: | Sat, 21 Feb 2015 12:31:29 -0800 |
Stuart -- thank for suggestion but grillparts.com doesn't list the model -- a "Superb by Broilmaster" Model SBH200-1 Natural Gas Grill. Near as I can tell, Broilmaster sold those w/o regulators to distributors who bunged in whatever regulator they had on hand, as the regulator is not in the owner/assembly manual's part number listing and shown only as a generic circular object labeled "regulator" in the assembly illustration. Phil, good point. We had a serviceman out here a couple years ago to diagnose a stove problem in the house and he measured the pressure and it was spot on at 7'' W.C. and the stove has not changed behavior since then so I suspect that the natural gas pressure is still good. The regulator on this BBQ is marked: "GLOBAL Model 7010 PSIG 1/2, Nat 4''-LPG 10'' " Which suggests a further step-down in pressure from 7'' W.C. to 4'' W.C. (How the regulator could be marked for two pressures begs a question: how does it know what kind of gas it is being fed so it can select between the two output pressures?) I suppose I /could/ try bypassing it, but the resulting flames from the burners might be more spectacular than normal, and unlikely to be the proper fuel / air ratio for a clean burn. Googling isn't helping find this part. Robertshaw makes a few kits that are said to fit the 7010 series of regulators, one labeled for dual fuels (but sez lpg 3.5'' and ng 11'') so it's not a solid fit although it does look physically like this device. Oh well, it's not Friday and this grill ain't a Vanagon and we can't pretend that it somehow qualifies for listworthiness because it's not even a propane grill. I'll have to keep looking. Many thanks, all. -- Jack "Rocket j Squirrel" Elliott 1984 Westfalia, auto trans, Bend, Ore. On 02/21/2015 11:18 AM, Phil Zimmerman wrote: > Date: Fri, 20 Feb 2015 15:47:06 -0800 > Reply-To: Rocket J Squirrel <camping.elliott@GMAIL.COM> > > On the barbecue. No, not a propane regulator, but a natural gas regulator. > > ------ Sometimes the regulator packs up and won't > open when the wall spigot is opened. I have to smack it with a spanner* > a couple times, and that don't always work, either�� > --------------- > > Jack, > > The above reads kinda strange.. > Why another regulator on the natural gas (NG) line to your natural gas barbie? > The NG system in your house already has a regulator at the main gas meter.. > > A NG spigot on a patio usually has a shut-off valve but not a regulator. > > NG runs at 3 inches of water column which is really low pressure. If the existing regulator > is sticking� this needs to be checked out�. and removed if redundant? > > Perhaps time for a licensed gas fitter to be called in to check this out� > Unless Jack wants to play mister science guy and mess around making a nanometer > to check the NG supply pressure at the patio gas line spigot.. > > Pz > hiding under his rock off the West Coast > (safe from NG explosions emitting from Bend, Oregon) > > =========== > * I use a natural gas regulator spanner, of course, not a propane > regulator spanner. Different ratings. > (yes, NG 3" of Water Column, LP 10-13" of WC) >
Have something to add on this topic today? Revive this thread in the forum »