Skip to main content
Gerry | Vanagon
Checking account...
← vanagon.com home · Continue the discussion in the forum
Subject:Re: Propane lines
From:David Beierl
Date:Sat, 4 Apr 2015 16:31:22 -0400

At 01:32 PM 4/3/2015, Michael wrote:
>Ok. So it sounds like the general consensus is that the whole line
>needs to be replaced.

Michael, the thing I haven't seen mentioned is that copper tubing
work-hardens very rapidly.  If you have to you can anneal it by
heating red hot and quenching in water.

Yours,
d