| Subject: | Followup to fridge troubles--success! |
| From: | Jim Felder |
| Date: | Fri, 22 May 2015 22:09:30 +0000 |
I posted during the week that my fridge would no longer operate on gas. Stuart described making a manometer, and thankfully the regulator was easily ruled out with a few bucks worth of clear tubing. I knew I had a noisy fan, so I ordered the beefy GoWesty replacement. It looks very good and was easy to install. I pulled the unit yesterday afternoon and cleaned the combustion chamber. Something flew out of the flue pipe when I put compressed air to them but I was not quick enough to see just what it was, I could hear it hit the combustion chamber pan. Maybe a leaf. You may recall that I had been in 70+ mph winds right before I began having problems. I opened the combustion chamber and it had a good bit of black grit inside the burner itself, and some around the chamber. Cleaned it all up and reinstalled the unit today. It now lights up no problem, and where it was doing good to pull a 20-25 degree difference from ambient, it was 86 today and the fridge temps hovered just over 40 degrees F. Very happy! Thanks to Stuart, Dennis and David B. Jim
Have something to add on this topic today? Revive this thread in the forum »