| Subject: | Re: GoWesty fridge fan report |
| From: | Poppie Jagersand |
| Date: | Wed, 10 Jun 2015 20:56:12 +0000 |
On Wednesday, June 10, 2015 5:47 AM, Jim Felder <jim.felder@GMAIL.COM> wrote: >But also as I installed the replacement fan I did everything one could >possibly do to the seals, the burner, and the flue. The flame roars so that >even I have no trouble hearing it with my ear anywhere near the flue vent >if I'm outside on the drivers side. How did you make the flame "roar"? Change the orfice in the burner? B.t.w. In my '82 Westy I removed the fibreglass insulation in the wall panel behind the fridge. This improved the fridge performance noticeably. (It didn't occur to me to to do before/after delta T measurements). I'm guessing the insulation removal behind the fridge might help in two ways: More room behind the fridge so more air to circulate. Additional cooling of the air behind from the now non-insulated metal wall. My '82 is white. This might not work on my gold color '85 or any dark colors. In the '85 I use a 50mBar regulator in place of the stock 30mBar, which increases the power to the fridge by 30% as I mentioned in a post 4 days ago. There is no change in sound; no roar at 50mBar. Martin
Have something to add on this topic today? Revive this thread in the forum »