| Subject: | Re: Thermostats...question(s) |
| From: | Don Hanson |
| Date: | Tue, 15 Sep 2015 13:02:01 -0700 |
What I was looking for, thanks.. All.. On Sep 15, 2015 12:23 PM, "David Beierl" <dbeierl@attglobal.net> wrote: > At 02:58 PM 9/12/2015, Don Hanson wrote: > >> Is there an accepted method to test the function of one of our double >> style thermostats? I am skeptical about the proper operation of my >> currently installed one.... lately....I have had some other issues with >> > > Put it in a pan of vegetable oil or 100% gycol antifreeze (caution: both > are flammable) and heat it on a stove. Opening begins ~85C/185F. Opening > complete ~105C/221F. Minimum opening stroke 8 mm/.35 in. > > Yrs, > d >
Have something to add on this topic today? Revive this thread in the forum »