Remy, Just one caveat; I'm assuming you still have the stock setup? The only real issue would be if you've done a conversion and are using an R-134A compressor (like I am). The original SD510 and SD710's are designed for R-12 and mineral oil. One thing I didn't mention - barrier hoses. If you do/did choose to go with R134A, you really need to replace all your rubber A/C hoses with "barrier" hoses to keep the R134A from leaking out through the hose material, and you'd need to replace the TXV (at the evaporator) with one calibrated for R134A. Not a lot of "win" in that situation if you're keeping stock components. BTW, I've had pretty good luck with Arizona Mobile Air (Ackits.com) if you're here in the Phx valley. Keith Hughes '86 Westy GenV (Marvin) ------------------------------ Date: Sat, 8 Apr 2017 04:53:39 -0700 From: Remy <remster2@YAHOO.COM> Subject: Re: vanagon Digest - 6 Apr 2017 to 7 Apr 2017 (#2017-129) Thanks Keith, I'll have them use R 12. Remy 85 Westy GL (Chippy) > On Apr 7, 2017, at 9:00 PM, Automatic digest processor <LISTSERV@GERRY.VAN= AGON.COM> wrote: >=20 > There are 2 messages totalling 84 lines in this issue. >=20 > Topics of the day: >=20 > 1. <No subject given> > 2. Van-Again getting a new store that supports many other languages >=20 >