| Subject: | Re: resurrection? |
| From: | Jim Felder |
| Date: | Tue, 11 Jul 2017 14:07:31 +0000 |
40 under ambient is normal, I think. Jim On Tue, Jul 11, 2017 at 8:57 AM David McNeely <davmcneely40@gmail.com> wrote: > Not a member of the list. Negra Modelo. > > Coldest the refrigerator got on propane was 4.4 C (40 F) at 6:00 a.m. this > morning after running for 16 hours. Ambient temperature this morning, 54 > F. That would be ok if ambient was always 54 F. > > Don't know where to go from here. > > mcneely > > On Mon, Jul 10, 2017 at 7:35 PM, Stacy Schneider <vwcrewman@gmail.com> > wrote: > > > Hopefully the guy is not a member of this list. I hope you offered him a > > proper beverage either hit or cold to his liking. > > > > Stacy > > > > Sent from my iPhone > > > > > On Jul 10, 2017, at 5:55 PM, David McNeely <davmcneely40@GMAIL.COM> > > wrote: > > > > > > Some of you may recall the incident where I knocked my Dometic 182b > > > refrigerator off the work table and it seemed to have died. The burner > > box > > > was cracked along one edge, the brazing for the drain tube to burner > box > > > was cracked, the tube was bent, and perhaps there were other damages. > > All > > > was due to my neighbors unfriendly dog entering my workshop while I was > > > working on the refrigerator. > > > > > > Before we left for camping last week, the neighbor, whom I had inferred > > > responded indifferently to the incident, came over to apologize for the > > > dog's behavior, and his abrupt departure without making inquiries > > > concerning consequences. He had wanted to get the dog safely > ensconced, > > > and had to depart for work. > > > > > > Turns out that work involves welding, and he also has his own > equipment. > > > He came over this morning, fashioned a new drain tube, brazed the > cracked > > > burner box and brazed the drain tube back properly. I had previously > > > cleaned the propane line to the burner box, though I am not sure how > > > adequately. I also found that the lack of 12 V power to the > refrigerator > > > was due to a loose connection that powers both the refrigerator and the > > > fresh water tank pump. > > > > > > When everything was properly hooked up and checked for leaks (none), > the > > > refrigerator started immediately on propane. Ambient temperature this > > > afternoon is 82 F. The refrigerator is cooling. We'll see how cold it > > > gets. > > > > > > mcneely > > >
Have something to add on this topic today? Revive this thread in the forum »