| Subject: | Re: Electrical puzzle |
| From: | David Beierl |
| Date: | Thu, 14 Jun 2018 18:43:05 -0400 |
He added a hard-start relay which interrupted a signal ground in the warning module that normally grounds through the starter solenoid. Fix is to separate the relay control from the rest at the panel and move all non-control functions back to the actual 50 wire. Details on Facebook VOG group.