| Subject: | Re: Electrical puzzle |
| From: | OlRivrRat |
| Date: | Sat, 16 Jun 2018 11:04:52 -0600 |
D
In a Solenoid Application, as We discussing here, If the Solenoid Resists Intended
Movement does that Initial Draw Increase ~ This is Info? not argument > You're the Wizard
on this stuff ~
ORR ~ DeanB
On 16 Jun , 2018, at 10:48 AM, David Beierl wrote:
> So far what I am finding is that Initial Current to extend the Solenoid can be in the 25-35Amp range
>
> That would bring the voltage drop along that 6mm^2 wire up to maybe 0.6V, still leaving 0.9V available for the rest of the positive path plus allowance for degradation.
>
> Don't misunderstand -- I love relays. I would put them everywhere. But that's not the same as saying that VAG *should* have used one. Fat wire alone, vs skinny wire and relay is an engineering choice.
>
> Yrs,
> dHave something to add on this topic today? Revive this thread in the forum »