Thank you David! This information is Gold ! Sent from Yahoo Mail on Android On Sun, Aug 12, 2018 at 5:40 PM, David Beierl<dbeierl@ATTGLOBAL.NET> wrote: > > With the temp gauge disconnected entirely, I either get the blinking at > startup and then no blink (and no reading for dash temp), or I get the > blinking at startup, with a temporary pause, then the constant blinking > with a hint of temp gauge movement. > Second condition says you have the newer level controller and it has triggered. > Am I correct in thinking that there's a short in the wire somewhere from > the pressure tank to the dash gauge? > Like that wire has worn against metal and is making contact? > No, if the sender line were grounded the controller would think everything was fine. The controller triggers when it's an open circuit between the sender lead and ground.** Bad contact at sender, bad ground at sender, bad contact at connector T7a pin three (green wire going to blue/green; inside wiring box on the firewall; broken wire, bad contact on fuse/relay panel pin K5 (pinout on Bentley 97.68), bad contact at level controller, painted number 42 or 43, third socket in the upper row of the fuse/relay panel, broken solder inside level controller. Yrs, d