| Subject: | Re: bad ground on radiator fan motor |
| From: | Thomas Casal |
| Date: | Sun, 29 Aug 2021 17:00:26 -0400 |
I was thinking that could be my other option. Thanks Mark On Sun, Aug 29, 2021 at 4:52 PM vw_van_fan_Mark <madvws@cox.net> wrote: > That fan has a brown ground wire and you could splice into that wire > with another #12 or #10 wire and screw the other end to bare metal on > the van body. > > Mark > > Thomas Casal wrote: > > Hey Guys, I'm Reviving an old thread here. I have an older style fan and > > was curious what the best way to add an extra ground is. Can I just > attach > > the wire to the body of the fan with a carefully placed screw? If not > what > > would be the best way to add an extra ground wire. My fan hasn't worked > in > > a minute I confirmed that the motor was good by jumpering it. Fan was > > intermittent for a while then totally died. > > > > > > On Thu, Jan 4, 2018 at 5:34 PM vw_van_fan_Mark <madvws@cox.net> wrote: > > > >> Yes, the failed rad fan ground connection has become pretty common > >> lately and often becomes intermittent first. I often add a dedicated > >> local ground wire but I drill a hole in the chassis nearby so anyone > >> working on the rad fan/wiring in the future can plainly see the added > >> ground point. > >> > >> >
Have something to add on this topic today? Revive this thread in the forum »