| Subject: | Re: Propex 1600 blowing fuses |
| From: | Mark McCulley |
| Date: | Sat, 30 Oct 2021 09:29:21 -0700 |
Gosh, I don't know exactly how old it is. It was part of the first batch or two that were sold in North America. I know it's at least 20 years old though and has been 100% reliable until now. I have a message in to Propex in the UK but have not heard back from them. I will also reach out to Van Cafe as they are a US dealer now. -Mark On Sat, Oct 30, 2021 at 8:54 AM David McNeely <davmcneely40@gmail.com> wrote: > Mark, how old is your heater? This gives me pause in thinking about > installing one in my own camper. A "stuck" fan is not an uncommon problem > with various appliances, but usually is readily remedied. No help from > Propex? So far as holes in the camper, seems you could reinstall the > heater, though dead for now, and at least not have the holes. mcneely > > On Sat, Oct 30, 2021 at 7:53 AM Mark McCulley <markmcculley@gmail.com> > wrote: > >> I did some more diagnosis, looks like the fan motor is the problem. First >> I >> removed the propane leak detector from the circuit, this did not make any >> difference, fuse still blew. It wasn't possible to remove the cover from >> the heater with it still installed so I pulled the heater from the van. >> Removing the heater cover was a minor challenge as parts of it were sealed >> to the chassis with silicone RTV. Once removed I was able to access the >> two >> squirrel cage fans and could just barely move them. I don't know if the >> shaft rusted or what happened but it barely moves. I applied some >> penetrating oil at both ends and let it sit for a while but that made no >> difference. I may or may not attempt a fix by removing the motor and >> disassembling it. Anyone have a broken model 1600 with a good motor? Very >> unlikely I know. :) >> >> Does anyone know if the newer HS2000 model has the same size and spacing >> of >> the exhaust and combustion air inlet/outlet tubes? It would be nice if it >> were a drop in replacement for the Compact 1600. >> >> I don't know what bothers me more...not having a heater for camping this >> winter or having two open holes through the floor of my van. >> >> -Mark >> >> On Fri, Oct 29, 2021 at 7:29 AM Mark McCulley <markmcculley@gmail.com> >> wrote: >> >> > My trusty Propex 1600 heater blew a fuse yesterday when I tried to start >> > it for the first time this year. The 5A fuse blows as soon as the unit >> > turns on, both in Heat mode and in Fan Only mode. This makes me suspect >> the >> > fan motor is the culprit. I have an inquiry in to Propex but I'd really >> > like to fix it myself if possible. Anyone ever experienced a similar >> issue >> > with the 1600? >> > >> > Regards, >> > Mark >> > >> >
Have something to add on this topic today? Revive this thread in the forum »