| Subject: | Re: Propex 1600 blowing fuses |
| From: | David Beierl |
| Date: | Sun, 31 Oct 2021 13:24:12 -0400 |
I like Zoom turbine oil (Amazon or appliance parts house). Yrs, d On Sat, Oct 30, 2021 at 5:19 PM Mark McCulley <markmcculley@gmail.com> wrote: > Progress! The two halves of the motor case were held together by the > magnets and were easily separated. Pulling the armature out was a bit > difficult, the bushing was seized to the shaft and came out with the shaft. > I carefully removed the bushing from the shaft with pliers and polished it > and the shaft with emery paper. It will now spin freely on the shaft. > > More photos here: https://www.icloud.com/sharedalbum/#B0QJ0DiRHJtI2mL > > Any suggestions on what kind of lube to use? I'm surprised that the > bushings aren't made of brass. > > Once the motor is back together I'll test it on the bench. Then I will have > to decide how comfortable I am with reassembling this thing and hooking it > up to a propane line. What could go wrong eh? > > -Mark > > On Sat, Oct 30, 2021 at 1:33 PM Mark McCulley <markmcculley@gmail.com> > wrote: > > > Dennis, how would I get to the bearings? I've disassembled the heater and > > removed the fan motor. Do I need to disassemble the motor? > > > > Some photos here: https://www.icloud.com/sharedalbum/#B0QJ0DiRHJtI2mL > > > > See the photo showing the end of the shaft, I wonder if that piece > > surrounding the shaft is scored so that it can be removed with some > special > > tool to get to the bearings? > > > > -Mark > > > > > > On Sat, Oct 30, 2021 at 9:33 AM Dennis Haynes <d23haynes57@hotmail.com> > > wrote: > > > >> It has been some time since I had one of these apart for repair. Gas jet > >> clogging is another common problem. In general DC fuses are sized and > >> coordinated to protect the wiring, not appliances themselves. Maybe > >> carefully lube the bearings avoiding oil on the brushes-commutator and > up > >> the fuse size and give the fans a push to get them turning. A synthetic > >> type light oil once the bearings spin again will work some magic. > >> Disappointing is that repair services and parts are not readily > available > >> considering the cost and how little these units are typically used. > >> > >> Dennis > >> > >> > >> -----Original Message----- > >> From: Vanagon Mailing List <vanagon@gerry.vanagon.com> On Behalf Of > Mark > >> McCulley > >> Sent: Saturday, October 30, 2021 10:53 AM > >> To: vanagon@GERRY.VANAGON.COM > >> Subject: Re: Propex 1600 blowing fuses > >> > >> I did some more diagnosis, looks like the fan motor is the problem. > First > >> I removed the propane leak detector from the circuit, this did not make > any > >> difference, fuse still blew. It wasn't possible to remove the cover from > >> the heater with it still installed so I pulled the heater from the van. > >> Removing the heater cover was a minor challenge as parts of it were > >> sealed to the chassis with silicone RTV. Once removed I was able to > access > >> the two squirrel cage fans and could just barely move them. I don't > know if > >> the shaft rusted or what happened but it barely moves. I applied some > >> penetrating oil at both ends and let it sit for a while but that made no > >> difference. I may or may not attempt a fix by removing the motor and > >> disassembling it. Anyone have a broken model 1600 with a good motor? > Very > >> unlikely I know. :) > >> > >> Does anyone know if the newer HS2000 model has the same size and spacing > >> of the exhaust and combustion air inlet/outlet tubes? It would be nice > if > >> it were a drop in replacement for the Compact 1600. > >> > >> I don't know what bothers me more...not having a heater for camping this > >> winter or having two open holes through the floor of my van. > >> > >> -Mark > >> > >> On Fri, Oct 29, 2021 at 7:29 AM Mark McCulley <markmcculley@gmail.com> > >> wrote: > >> > >> > My trusty Propex 1600 heater blew a fuse yesterday when I tried to > >> > start it for the first time this year. The 5A fuse blows as soon as > >> > the unit turns on, both in Heat mode and in Fan Only mode. This makes > >> > me suspect the fan motor is the culprit. I have an inquiry in to > >> > Propex but I'd really like to fix it myself if possible. Anyone ever > >> > experienced a similar issue with the 1600? > >> > > >> > Regards, > >> > Mark > >> > > >> > > >
Have something to add on this topic today? Revive this thread in the forum »