| Subject: | Re: An electrical thing I never noticed in 20 years of Westy ownership Another Westy Fridge Design Flaw |
| From: | Alistair Bell |
| Date: | Mon, 1 Aug 2022 08:10:34 -0700 |
Or just pull that fuse in the little box at the drivers side b pillar. Or a switch there Alistair > On Aug 1, 2022, at 8:09 AM, Jim Felder <jim.felder@gmail.com> wrote: > > The surprise for me is that there is not a cut-out for the fan circuit at > any place where there could be one. > > Maybe a high-temp switch near the burner and a relay for the electric modes? > > Jim > >> On Mon, Aug 1, 2022 at 10:05 AM Alistair Bell <albell@shaw.ca> wrote: >> >> What I did some years ago, was to take out the stick thermo switch on the >> back fins and replace with thermo probe for a programable tstat. Was during >> my ongoing effort to make the propane fridge work a wee bit better. >> >> I thought I’d play with lower temp setting for the fan to come on. Last >> year I replaceded the original , kinda clunky , programable unit for a >> slimmer inkbird brand one. >> >> I wasn’t convinced that adjusting the fan set point really did much. But >> the obvious benefit was the fan would stay off if the control unit was off. >> No runaway fan on a hot day thing, that this thread is about. >> >> Funny how it’s still a surprise for some that the stock fan works that >> way :-) >> >> Alistair >> >>> On Jul 31, 2022, at 12:46 PM, Jeff Palmer <w.jeff.palmer@icloud.com> >> wrote: >>> >>
Have something to add on this topic today? Revive this thread in the forum »