Subject:Re: Installing an override switch on the vanagon radiator sensor
From:OlRivrRat
Date:Tue, 7 Mar 2023 16:34:18 -0700

Dan & TWeEIMC

        Did Just that not long after I got My 1st H2OBoxer back in ’83 & also did it to My ’90 not long after I got it in ’06,,, Mine are connected to the High Speed circuit since My aim was to be able to switch the fan on high as I would be approaching a significant climb while loaded with a bunch of boating & camping gear & with a Canoe or 2 on the roof rack & a Raft trailer with a Raft or 2 hitched to the rear, in order to keep the Cooling System from even thinking a little bit about heading for high temps,,, It has worked out great for many years & I have also considered on numerous occasions about replacing the Single Throw switch with a Double Throw switch to provide manual control of the Low Speed as well ~
Using “T-Tap” on the wires right @ the Radiator Sensor/Switch makes for a very simple way to do the mod’ ~ If You are not familiar with “T-Tap” just Google it ~

                                                        ORR ~ DeanB

> On 7 Mar , 2023, at 2:17 PM, Dan N <dn92610@GMAIL.COM> wrote:
> 
> hi all,
> 
> I am thinking about installing an override switch on the vanagon radiator
> sensor so I can turn the fan ON/OFF whenever I want. The van is a 1990 2.1
> WBX, no A/C.... in case the sensor fails.
> 
> Would using 2 wires from the toggle switch and attaching them on the 2
> wires on the sensor at the bottom of the radiator work? Any risk or problem?
> 
> thank you,
> 
> dan