| Subject: | Re: Microscopic corrosion on electrical contacts |
| From: | Richard Koerner |
| Date: | Thu, 15 Jun 2023 00:46:00 +0000 |
I think either one would work fine in most applications. The point is: just bare metal?, or bare metal with some kind of protection barrier against incoming humid air. Consider a simple 1/4" Male blade connector, with a matching 1/4" Female connector. With some sort of greasy coating, the two connect together, metal against metal. But what is happening is that a very tiny fillet of greasy coating forms along both sides of the sharp metal to metal connection as the two are shoved together, and this is what helps prevent corrosion. A barrier. This is my theory anyway. Without this coating, you have a very nice crevice for water molecules to lodge and start to go to work.
On Wednesday, June 14, 2023 at 05:22:38 PM PDT, Jim Felder <jim.felder@gmail.com> wrote:
Vaseline does t last very long, dielectric grease does.
Jim
Sent from my iPhone
> On Jun 14, 2023, at 5:27 PM, David McNeely <davmcneely40@gmail.com> wrote:
>
> vaseline?
>
> On Wed, Jun 14, 2023 at 12:41 PM Richard Koerner <rjkinpb@sbcglobal.net>
> wrote:Have something to add on this topic today? Revive this thread in the forum »