| Subject: | Re: gas tank leak check |
| From: | Gabriel Hourtouat |
| Date: | Fri, 30 Jun 2023 00:35:52 -0400 |
FAIL, but not bad. Pressure leaked from 1.3"Hg to 1"Hg in about 40 seconds (spec calls for 5 minutes for that pressure decay); but then it stayed at around 0.44"Hg for about 5 minutes. My leak checking apparatus ws leaking, too. So, I'm happy. Much better than it was. Doesn't smell anymore. I recommend the process. Cheers, gabby 86 wbx On Thu, Jun 29, 2023 at 1:39 PM Gabriel Hourtouat <ghourtouat@gmail.com> wrote: > new seals on the gas tank and vents etc. > -leak checking, found a hole in one of the pipe nipples on a new vent > tank. > -trying a fix with epoxy. marine grade. says it's good for pvc. > -does the system EVER meet spec -- 1"HG? > gabby >