Skip to main content
Gerry | Vanagon
Checking account...
← vanagon.com home · Continue the discussion in the forum
Subject:Re: Blowing kitchen w. pump fuses - help!
From:Jack Reed
Date:Tue, 11 Jul 1995 12:43:56 -0600 (MDT)

Stuart,

On Tue, 11 Jul 1995, Stuart Hutton wrote:

> > the fuse blows.  My pump usually "freezes" up between Winter and Spring, 
> > due to the lack of internal lubrication (water) no doubt.  The current 
> > flow through the pump switch isn't enough to "unfreeze" it so I snake my 
> 
> I hate to let you know this, but when I took my pump apart under similar
> circumstances, I got sick to think I had drunk the water that the pump
> was in.  If your pump does freeze up, it is getting water in the motor.
> The water will be very very nasty.  I mean really nasty.
> Stuart
> 

I suppose a better word than freeze would have been "sticks".  The 
bearings and wotnot dry out over the Winter and there's too much 
resistance in the lines to supply enough current to break things loose.  
This is a new motor and I've gotten no indications, either by water color 
or taste, that things are awry with the motor itself.  YMMV, tho.

Additionally, although you don't state it, it sounds like your pump 
failed altogether, rather than just needed the extra kick that the higher 
current from the cables supplied.  In which case you'd be right in your 
assessment.

Jack